Click here to see reports of other supported models from Legrand.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.2

Report #1

This device is known to work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.voltage

13.20

battery.voltage.high

13.00

battery.voltage.low

10.40

battery.voltage.nominal

12.0

device.type

ups

driver.name

nutdrv_qx

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.7.2

driver.version.data

Voltronic-QS 0.01

driver.version.internal

0.06

input.current.nominal

3.0

input.frequency

50.0

input.frequency.nominal

50

input.voltage

227.9

input.voltage.fault

226.1

input.voltage.nominal

230

output.voltage

226.1

ups.beeper.status

enabled

ups.delay.shutdown

30

ups.delay.start

180

ups.firmware.aux

PMV

ups.productid

5161

ups.status

OL

ups.type

offline / line interactive

ups.vendorid

0665

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.toggle

  • load.off

  • load.on

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start.quick

2.7.1

Report #1

This device is known to work with driver blazer_usb. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.voltage

13.70

battery.voltage.high

13.00

battery.voltage.low

10.40

battery.voltage.nominal

12.0

device.type

ups

driver.name

blazer_usb

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.7.1

driver.version.internal

0.10

input.current.nominal

3.0

input.frequency

49.6

input.frequency.nominal

50

input.voltage

222.4

input.voltage.fault

222.4

input.voltage.nominal

230

output.voltage

224.2

ups.beeper.status

enabled

ups.delay.shutdown

30

ups.delay.start

180

ups.productid

5161

ups.status

OL

ups.type

offline / line interactive

ups.vendorid

0665

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.toggle

  • load.off

  • load.on

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop