Report #1
This device is known to work with driver mge-shut.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.capacity
|
|
battery.charge
|
|
battery.charge.low
|
|
battery.charge.restart
|
|
battery.energysave
|
|
battery.protection
|
|
battery.runtime
|
|
battery.type
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.offdelay
|
|
driver.parameter.ondelay
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.bypass.current
|
|
input.bypass.voltage
|
|
input.frequency
|
|
input.frequency.nominal
|
|
input.voltage
|
|
input.voltage.nominal
|
|
outlet.1.autoswitch.charge.low
|
|
outlet.1.delay.shutdown
|
|
outlet.1.delay.start
|
|
outlet.1.desc
|
|
outlet.1.id
|
|
outlet.1.status
|
|
outlet.1.switchable
|
|
outlet.2.autoswitch.charge.low
|
|
outlet.2.delay.shutdown
|
|
outlet.2.delay.start
|
|
outlet.2.desc
|
|
outlet.2.id
|
|
outlet.2.status
|
|
outlet.2.switchable
|
|
outlet.desc
|
|
outlet.id
|
|
outlet.switchable
|
|
output.current
|
|
output.frequency
|
|
output.frequency.nominal
|
|
output.powerfactor
|
|
output.voltage
|
|
output.voltage.nominal
|
|
ups.alarm
|
Just replaced the battery. |
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.firmware
|
|
ups.load
|
|
ups.load.high
|
|
ups.mfr
|
|
ups.model
|
|
ups.power
|
|
ups.power.nominal
|
|
ups.productid
|
|
ups.realpower
|
|
ups.realpower.nominal
|
|
ups.serial
|
|
ups.start.auto
|
|
ups.start.battery
|
|
ups.start.reboot
|
|
ups.status
|
Just replaced the battery; unable to get rid of the |
ups.test.interval
|
|
ups.test.result
|
|
ups.timer.shutdown
|
|
ups.timer.start
|
|
ups.type
|
|
ups.vendorid
|
|
2.4.3
Report #1
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.capacity
|
|
battery.charge
|
|
battery.charge.low
|
|
battery.charge.restart
|
|
battery.energysave
|
|
battery.protection
|
|
battery.runtime
|
|
battery.type
|
|
device.mfr
|
|
device.model
|
|
device.serial
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.bypass.current
|
|
input.bypass.voltage
|
|
input.frequency
|
|
input.frequency.nominal
|
|
input.voltage
|
|
input.voltage.nominal
|
|
outlet.1.autoswitch.charge.low
|
|
outlet.1.delay.shutdown
|
|
outlet.1.delay.start
|
|
outlet.1.desc
|
|
outlet.1.id
|
|
outlet.1.status
|
|
outlet.1.switchable
|
|
outlet.2.autoswitch.charge.low
|
|
outlet.2.delay.shutdown
|
|
outlet.2.delay.start
|
|
outlet.2.desc
|
|
outlet.2.id
|
|
outlet.2.status
|
|
outlet.2.switchable
|
|
outlet.desc
|
|
outlet.id
|
|
outlet.switchable
|
|
output.current
|
|
output.frequency
|
|
output.frequency.nominal
|
|
output.powerfactor
|
|
output.voltage
|
|
output.voltage.nominal
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.firmware
|
|
ups.load
|
|
ups.load.high
|
|
ups.mfr
|
|
ups.model
|
|
ups.power
|
|
ups.power.nominal
|
|
ups.productid
|
|
ups.realpower
|
|
ups.realpower.nominal
|
|
ups.serial
|
|
ups.start.auto
|
|
ups.start.battery
|
|
ups.start.reboot
|
|
ups.status
|
|
ups.test.interval
|
|
ups.test.result
|
|
ups.timer.shutdown
|
|
ups.timer.start
|
|
ups.type
|
|
ups.vendorid
|
|
2.2.0
Report #1
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.charge.low
|
|
battery.charge.restart
|
|
battery.runtime
|
|
battery.type
|
|
battery.voltage
|
|
driver.name
|
|
driver.parameter.offdelay
|
|
driver.parameter.ondelay
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.frequency
|
|
input.voltage
|
|
outlet.0.desc
|
|
outlet.0.id
|
|
outlet.0.switchable
|
|
outlet.1.autoswitch.charge.low
|
|
outlet.1.delay.shutdown
|
|
outlet.1.delay.start
|
|
outlet.1.desc
|
|
outlet.1.id
|
|
outlet.1.status
|
|
outlet.1.switchable
|
|
outlet.2.autoswitch.charge.low
|
|
outlet.2.delay.shutdown
|
|
outlet.2.delay.start
|
|
outlet.2.desc
|
|
outlet.2.id
|
|
outlet.2.status
|
|
outlet.2.switchable
|
|
output.current
|
|
output.frequency
|
|
output.voltage
|
|
output.voltage.nominal
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
|
ups.delay.start
|
|
ups.load
|
|
ups.mfr
|
|
ups.model
|
|
ups.power.nominal
|
|
ups.productid
|
|
ups.serial
|
|
ups.status
|
|
ups.test.interval
|
|
ups.test.result
|
|
ups.vendorid
|
|