Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from MGE UPS SYSTEMS.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.1

Report #1

This device is known to work with driver mge-shut.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

30

battery.runtime

456

device.mfr

MGE UPS SYSTEMS

device.model

ellipse premium 800

device.serial

unknown

device.type

ups

driver.name

mge-shut

driver.parameter.pollinterval

2

driver.parameter.port

/dev/cuau0

driver.version

2.6.1

driver.version.internal

0.69

outlet.1.autoswitch.charge.low

0

This variable can be set through upsrw to a string value.

outlet.1.desc

PowerShare Outlet 1

This variable can be set through upsrw to a string value.

outlet.1.id

2

outlet.1.switch

1

This variable can be set through upsrw to a string value.

outlet.1.switchable

1

outlet.desc

Main Outlet

This variable can be set through upsrw to a string value.

outlet.id

1

outlet.switchable

0

output.voltage

230

ups.load

40

ups.mfr

MGE UPS SYSTEMS

ups.model

ellipse premium 800

ups.power.nominal

800

ups.serial

unknown

ups.status

OL CHRG

ups.timer.shutdown

-1

This variable can be set through upsrw to a string value.

ups.timer.start

-1

This variable can be set through upsrw to a string value.

Known supported commands

This device is known to support the following NUT’s instant commands:

  • load.off

  • load.on

  • shutdown.return

  • shutdown.stayoff

  • test.battery.start

  • test.battery.stop

Report #2

This device is known to work with driver newmge-shut, now replaced by the mge-shut one.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

30

battery.runtime

456

battery.type

PbAc

device.mfr

MGE UPS SYSTEMS

device.model

ellipse premium 800

device.serial

unknown

device.type

ups

driver.name

newmge-shut

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

/dev/cuau0

driver.version

2.6.1

driver.version.data

MGE HID 1.21

driver.version.internal

0.35

input.transfer.high

264

input.transfer.low

161

outlet.1.desc

PowerShare Outlet 1

outlet.1.id

2

outlet.1.status

on

outlet.1.switchable

yes

outlet.desc

Main Outlet

outlet.id

2

outlet.switchable

no

output.frequency.nominal

50

output.voltage

230.0

output.voltage.nominal

161

This variable can be set through upsrw to one of the following values:

  • 200

  • 208

  • 220

  • 230

  • 240

  • 100

  • 110

  • 120

  • 127

ups.delay.shutdown

20

ups.delay.start

30

ups.load

42

ups.mfr

MGE UPS SYSTEMS

ups.model

ellipse premium 800

ups.power.nominal

800

ups.productid

ffff

ups.serial

unknown

ups.status

OL CHRG BOOST

ups.timer.shutdown

-1

ups.timer.start

-10

ups.vendorid

0463