Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from MGE UPS SYSTEMS.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.2

Report #1

This device is known to work with driver mge-shut.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

20

battery.runtime

5400

device.mfr

MGE UPS SYSTEMS

device.model

Pulsar Evolution 3000

device.serial

AF3E39202

device.type

ups

driver.name

mge-shut

driver.parameter.pollinterval

2

driver.parameter.port

/dev/ups0

driver.version

2.6.2

driver.version.internal

0.69

input.frequency

50

input.voltage

240

outlet.1.autoswitch.charge.low

0

outlet.1.delay.shutdown

-1

outlet.1.delay.start

-1

outlet.1.desc

PowerShare Outlet 1

outlet.1.id

1

outlet.1.switch

1

outlet.1.switchable

1

outlet.2.autoswitch.charge.low

0

outlet.2.delay.shutdown

-1

outlet.2.delay.start

-1

outlet.2.desc

PowerShare Outlet 2

outlet.2.id

2

outlet.2.switch

1

outlet.2.switchable

1

outlet.desc

Main Outlet

outlet.id

0

outlet.switchable

0

output.frequency

50

output.voltage

237

output.voltage.nominal

72

ups.load

10

ups.mfr

MGE UPS SYSTEMS

ups.model

Pulsar Evolution 3000

ups.power.nominal

3000

ups.serial

AF3Ennnnn

ups.status

OL CHRG

ups.test.result

Done and passed

ups.timer.shutdown

-1

ups.timer.start

-1

2.6.1

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

20

battery.charge.restart

0

battery.energysave

no

battery.protection

yes

battery.runtime

5400

battery.type

PbAc

device.mfr

MGE UPS SYSTEMS

device.model

Pulsar Evolution 3000

device.serial

AF3Ennnnn

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.productid

ffff

driver.parameter.vendorid

0463

driver.version

2.6.1

driver.version.data

MGE HID 1.21

driver.version.internal

0.35

input.frequency

50.0

input.frequency.extended

no

input.frequency.nominal

50

input.sensitivity

normal

input.transfer.boost.low

184

input.transfer.high

294

input.transfer.low

160

input.transfer.trim.high

265

input.voltage

238.0

input.voltage.extended

no

input.voltage.nominal

230

outlet.1.autoswitch.charge.low

0

outlet.1.delay.shutdown

65535

outlet.1.delay.start

3

outlet.1.desc

PowerShare Outlet 1

outlet.1.id

1

outlet.1.status

on

outlet.1.switchable

yes

outlet.2.autoswitch.charge.low

0

outlet.2.delay.shutdown

65535

outlet.2.delay.start

6

outlet.2.desc

PowerShare Outlet 2

outlet.2.id

2

outlet.2.status

on

outlet.2.switchable

yes

outlet.desc

Main Outlet

outlet.id

0

outlet.switchable

no

output.current

1.00

output.current.nominal

13.04

output.frequency

50.0

output.frequency.nominal

50

output.voltage

236.0

output.voltage.nominal

230

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.delay.start

30

ups.load

10

ups.mfr

MGE UPS SYSTEMS

ups.model

Pulsar Evolution 3000

ups.power

210

ups.power.nominal

3000

ups.productid

ffff

ups.realpower.nominal

2000

ups.serial

AF3E39202

ups.start.auto

yes

ups.start.battery

yes

ups.start.reboot

yes

ups.status

OL CHRG

ups.test.interval

604800

ups.test.result

Done and passed

ups.timer.shutdown

-1

ups.timer.start

-10

ups.type

offline / line interactive

ups.vendorid

0463

2.0.1

Report #1

This device is known to work with driver mge-utalk.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100.0

battery.charge.low

30

battery.runtime

00876

battery.voltage

081.6

battery.voltage.nominal

072.0

driver.name

mge-utalk

driver.parameter.port

/dev/tty00

driver.version

2.0.1

driver.version.internal

0.81.0

input.frequency

60.00

input.transfer.boost.low

102.0

input.transfer.high

132.0

input.transfer.low

102.0

input.transfer.trim.high

132.0

input.voltage

122.8

output.current

010.3

output.voltage

122.2

ups.delay.shutdown

020

ups.delay.start

001

ups.firmware

unknown

ups.id

Evolutio 3000 17

ups.load

049.0

ups.mfr

MGE UPS SYSTEMS

ups.model

Evolution 3000

ups.status

OL CHRG

ups.test.interval