Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Online.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.6.3

Report #1

This device is known to work with driver blazer_usb. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

13.40

beeper.status

disabled

device.type

ups

driver.name

blazer_usb

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.productid

0002

driver.parameter.protocol

zinto

driver.parameter.subdriver

cypress

driver.parameter.vendorid

06da

driver.version

2.6.3

driver.version.internal

0.04

input.frequency

50.0

input.voltage

232.0

input.voltage.fault

1.0

output.voltage

232.0

ups.delay.shutdown

30

ups.delay.start

180

ups.load

0

ups.productid

0002

ups.status

OL BYPASS

ups.temperature

25.0

Temperature is always 25.0 (°C).

ups.type

offline / line interactive

ups.vendorid

06da

2.3.0

Report #1

This device is known to work with driver megatec_usb, now replaced by the blazer_usb one. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

13.30

driver.name

megatec_usb

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.3.0

driver.version.internal

1.5.14

input.frequency

49.9

input.voltage

229.0

input.voltage.fault

0.0

input.voltage.maximum

235.0

input.voltage.minimum

228.0

output.voltage

228.0

ups.beeper.status

disabled

ups.delay.shutdown

0

ups.delay.start

2

ups.load

45.0

ups.mfr

unknown

ups.model

unknown

ups.serial

unknown

ups.status

OL TRIM

ups.temperature

25.0

ups.type

standby