2.2.1

Report #1

This device is known to work with driver megatec_usb, now replaced by the blazer_usb one. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

89.8

battery.voltage

11.50

battery.voltage.nominal

11.5

driver.name

megatec_usb

driver.parameter.battvolts

0.0:12.8

driver.parameter.mfr

Plexus

driver.parameter.model

500VA

driver.parameter.pollinterval

2

driver.parameter.port

/dev/usb/hiddev0

driver.parameter.vendorid

0001

driver.version

2.2.1-

driver.version.internal

1.5.9

input.frequency

50.0

input.voltage

0.0

input.voltage.fault

165.0

output.voltage

230.0

output.voltage.nominal

230.0

ups.beeper.status

disabled

ups.delay.shutdown

0

ups.delay.start

2

ups.load

100.0

ups.mfr

Plexus

ups.model

500VA

ups.serial

unknown

ups.status

OB

ups.temperature

0.0

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.toggle

  • load.off

    Not working

  • load.on

    Not working

  • reset.input.minmax

    Not tested

  • reset.watchdog

    Not tested

  • shutdown.return

    Not working

  • shutdown.stayoff

    Not working

  • shutdown.stop

    Not working

  • test.battery.start

    Not working

  • test.battery.start.deep

    Not working

  • test.battery.stop

    Not working