Click here to see reports of other supported models from PowerWalker.
When a user reports that a variable/command is not right then it will be highlighted by a red underline. Bad values/ranges/etc… will get a red dashed outline or red solid left border. The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left. |
2.7.4
Report #1
This device is known to work with driver nutdrv_qx.
You can grab a dummy-ups compliant .dev
file to simulate this device clicking here.
Known supported variables
This device is known to support the following variables (values are just examples):
battery.charge
|
|
battery.energysave
|
This variable can be set through upsrw to one of the following values:
|
battery.packs
|
This variable can be set through upsrw within the following ranges:
|
battery.protection
|
This variable can be set through upsrw to one of the following values:
|
battery.runtime
|
|
battery.voltage
|
|
battery.voltage.nominal
|
|
device.model
|
|
device.type
|
|
driver.name
|
|
driver.parameter.pollfreq
|
|
driver.parameter.pollinterval
|
|
driver.parameter.port
|
|
driver.parameter.synchronous
|
|
driver.version
|
|
driver.version.data
|
|
driver.version.internal
|
|
input.current.nominal
|
|
input.frequency
|
|
input.frequency.high
|
This variable can be set through upsrw within the following ranges:
|
input.frequency.low
|
This variable can be set through upsrw within the following ranges:
|
input.frequency.nominal
|
|
input.phases
|
|
input.transfer.high
|
This variable can be set through upsrw within the following ranges:
|
input.transfer.high.max
|
|
input.transfer.high.min
|
|
input.transfer.low
|
This variable can be set through upsrw within the following ranges:
|
input.transfer.low.max
|
|
input.transfer.low.min
|
|
input.voltage
|
|
input.voltage.nominal
|
|
outlet.0.switchable
|
This variable can be set through upsrw to one of the following values:
|
output.current
|
|
output.current.nominal
|
|
output.frequency
|
|
output.frequency.nominal
|
|
output.phases
|
|
output.power.maximum.percent
|
|
output.power.minimum.percent
|
|
output.powerfactor
|
|
output.voltage
|
|
output.voltage.nominal
|
|
ups.beeper.status
|
|
ups.delay.shutdown
|
This variable can be set through upsrw within the following ranges:
|
ups.delay.start
|
This variable can be set through upsrw within the following ranges:
|
ups.firmware
|
|
ups.firmware.aux
|
|
ups.load
|
|
ups.power.nominal
|
|
ups.productid
|
|
ups.start.auto
|
This variable can be set through upsrw to one of the following values:
|
ups.start.battery
|
This variable can be set through upsrw to one of the following values:
|
ups.status
|
|
ups.temperature
|
|
ups.type
|
|
ups.vendorid
|
|
Known supported commands
This device is known to support the following NUT’s instant commands:
-
beeper.disable
-
beeper.enable
-
beeper.toggle
-
bypass.start
-
bypass.stop
-
load.off
-
load.on
-
shutdown.return
-
shutdown.stayoff
-
shutdown.stop
-
test.battery.start
-
test.battery.start.deep
-
test.battery.start.quick
-
test.battery.stop