Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from PowerWalker.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.7.3

Report #1

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.runtime

1567

battery.type

PbAc

battery.voltage

14

device.mfr

PPC

device.model

OfflineUPS

device.serial

000000000

literally all "0"

device.type

ups

driver.name

usbhid-ups

driver.parameter.pollfreq

30

still some COMMBAD dropouts with pollfreq=40/pollinterval=20

driver.parameter.pollinterval

15

driver.parameter.port

auto

driver.parameter.synchronous

no

driver.version

2.7.3

driver.version.data

Phoenixtec/Liebert HID 0.3

driver.version.internal

0.39

ups.load

20

ups.mfr

PPC

ups.model

Offline UPS

ups.productid

ffff

ups.serial

000000000

ups.status

OL CHRG

ups.vendorid

06da

About this device

Shutdown sequence tested on FreeNAS-9.10.2-U1 (86c7ef5) successfully. Emails from FreeNAS received notifying of On Batt and Shutdown.