Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Powerware.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.4.1

Report #1

This device is known to work with driver bcmxcp_usb.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

ambient.temperature

40

ambient.temperature.high

40

battery.charge

100

battery.runtime

2610

battery.voltage

54.9

driver.name

bcmxcp_usb

driver.parameter.pollinterval

2

driver.parameter.port

/dev/usb8

driver.parameter.shutdown_delay

120

driver.version

2.4.1

driver.version.internal

0.21

input.frequency

50.0

input.frequency.high

52

input.frequency.low

48

input.frequency.nominal

50

input.transfer.boost.high

176

input.transfer.high

276

input.transfer.low

160

input.transfer.trim.low

254

input.voltage

228

input.voltage.nominal

220

outlet.1.delay.shutdown

-1

This variable can be set through upsrw to a string value.

outlet.1.delay.start

60

This variable can be set through upsrw to a string value.

outlet.1.id

1

outlet.1.status

On

outlet.2.delay.shutdown

-1

This variable can be set through upsrw to a string value.

outlet.2.delay.start

60

This variable can be set through upsrw to a string value.

outlet.2.id

2

outlet.2.status

On

output.current

1.6

output.current.nominal

6.8

output.frequency

50.0

output.phases

1

output.voltage

221

output.voltage.nominal

220

ups.beeper.status

enabled

ups.firmware

Cont:02.05 Inve:02.05

ups.load

22.9

ups.model

PW9120 1500VA

ups.power

344

ups.power.nominal

1500

ups.serial

RY095A0163

ups.status

OL

Known supported commands

This device is known to support the following NUT’s instant commands:

  • outlet.1.shutdown.return

  • outlet.2.shutdown.return

  • shutdown.return

  • shutdown.stayoff

  • test.battery.start

2.2.2

Report #1

This device is known to work with driver snmp-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100.0

battery.runtime

23040.0

battery.runtime.low

2

battery.voltage

26.3

driver.name

snmp-ups

driver.parameter.mibs

ietf

driver.parameter.pollinterval

2

driver.parameter.port

166.99.224.144

driver.version

2.2.2

driver.version.internal

0.421 (mib: ietf 1.2)

input.frequency

50.0

input.phases

1.0

input.voltage

236.0

output.frequency

50.0

output.phases

1.0

output.realpower

0.3

output.voltage

230.0

ups.firmware

FP: 2.60 INV: 2.60

ups.firmware.aux

ConnectUPS Web/SNMP Card V4.26

ups.load

0.0

ups.mfr

Powerware Corporation

ups.model

PW9120

ups.power

3.0

ups.serial

ID: RA384A0447 , Msg: 05147361-5591

ups.status

OL