Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from Tripp Lite.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.4.3

Report #1

This device is known to work with driver tripplite_usb.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge doesn’t report correct charge level when the UPS is On Battery. It just reports 0, even though it will report 100 when on line power.

battery.voltage

27.40

battery.voltage.nominal

24

device.mfr

Tripp Lite

device.model

SMART1000RM2U

device.type

ups

driver.name

tripplite_usb

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.product

.*SMART1000RM2U.*

driver.version

2.4.3

driver.version.internal

0.20

input.frequency

60.0

input.frequency.nominal

60

input.voltage

115

input.voltage.maximum

123

input.voltage.minimum

0

input.voltage.nominal

120

outlet.1.desc

Load 1

outlet.1.id

1

outlet.1.switch

1

outlet.1.switchable

1

outlet.2.desc

Load 2

outlet.2.id

2

outlet.2.switch

1

outlet.2.switchable

1

outlet.3.desc

Load 3

outlet.3.id

3

outlet.3.switchable

0

ups.debug.D

37 35 38 41 0d 00 00 '758A...'

ups.debug.S

31 34 30 00 64 30 0d '140.d0.'

ups.debug.T

38 44 32 35 38 31 0d '8D2581.'

ups.debug.V

31 30 34 32 58 58 0d '1042XX.'

ups.debug.load_banks

2

ups.delay.shutdown

64

ups.firmware

F1218.A

ups.firmware.aux

protocol 3003

ups.id

65535

ups.load

19

ups.mfr

Tripp Lite

ups.model

SMART1000RM2U

ups.power.nominal

1000

ups.productid

0001

ups.status

OL

ups.temperature

30.3

ups.vendorid

09ae