2.6.1

Report #1

This device is known to work with driver blazer_usb. It may also work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.voltage

28.60

battery.voltage.nominal

24.0

beeper.status

disabled

device.mfr

UNITEK

device.model

Alph1200Sx

device.type

ups

driver.name

blazer_usb

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.version

2.6.1

driver.version.internal

0.03

input.current.nominal

4.3

input.frequency

50.0

input.frequency.nominal

50

input.voltage

230.0

input.voltage.fault

230.0

input.voltage.nominal

230

output.voltage

202.0

ups.delay.shutdown

30

ups.delay.start

180

ups.firmware

A1

ups.load

5

ups.mfr

UNITEK

ups.model

Alph1200Sx

ups.productid

0001

ups.status

OL

ups.temperature

32.0

ups.type

offline / line interactive

ups.vendorid