Report #1 with driver nutdrv_qx (detailed comments available)

This device is known to work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

71

battery.energysave

no

This variable can be set through upsrw to one of the following values:

  • no

  • yes

battery.packs

1

This variable can be set through upsrw within the following ranges:

  • 1..99

battery.runtime

19380

with no load attached

battery.voltage

054.4

battery.voltage.high

52.00

not reported by the UPS, driver guesstimation

battery.voltage.low

41.60

not reported by the UPS, driver guesstimation

battery.voltage.nominal

48.0

device.model

WPHVT2K0

device.serial

REDACTED

device.type

ups

driver.debug

0

driver.flag.allow_killpower

0

driver.name

nutdrv_qx

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

COM6

driver.parameter.protocol

voltronic

driver.parameter.synchronous

auto

driver.state

updateinfo

driver.version

2.8.5.1780.8-1788+g6fa23506c

driver.version.data

Voltronic 0.15

driver.version.internal

0.57

driver.version.usb

libusb-1.0.28 (API: 0x0100010A)

input.frequency

50.0

input.phases

1

input.voltage

224.4

input.voltage.nominal

230.0

output.current

0.0

output.current.nominal

8

output.frequency

50.0

output.frequency.nominal

50.0

output.phases

1

output.power.maximum.percent

0

output.power.minimum.percent

0

output.powerfactor

0.9

output.voltage

230.0

output.voltage.nominal

230.0

ups.beeper.status

enabled

ups.delay.shutdown

30

This variable can be set through upsrw within the following ranges:

  • 12..5940

ups.delay.start

180

This variable can be set through upsrw within the following ranges:

  • 0..599940

ups.firmware

03774.06

ups.firmware.aux

P01

ups.load

0

ups.power.nominal

2000

ups.start.auto

yes

This variable can be set through upsrw to one of the following values:

  • no

  • yes

ups.start.battery

yes

This variable can be set through upsrw to one of the following values:

  • no

  • yes

ups.status

OL

ups.temperature

19.3

ups.type

online

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • beeper.toggle

  • bypass.start

  • bypass.stop

  • load.off

  • load.on

  • shutdown.default

  • shutdown.return

  • shutdown.stayoff

  • shutdown.stop

  • test.battery.start

  • test.battery.start.deep

  • test.battery.start.quick

  • test.battery.stop

About this device

Device dump of an APC/Schneider Electric Easy UPS On-Line SRV2KI-E (2000 VA / 1800 W, 230 V, 4x 12 V batteries), collected on 2026-11-20 with NUT for Windows master snapshot 2.8.5.6042 (driver.version below).

The -E generation of the Easy UPS On-Line SRV series is a Voltronic OEM platform: QPI returns (PI01, QMD returns model WPHVT2K0 (the same string as reported by the FSP Fortron UPS Champ 2000VA Tower in this DDL).

Connection: built-in USB port, which is an Exar XR21V1410 USB-UART bridge (USB ID 04e2:1410), 2400 8N1. On Windows the MaxLinear xrusbser driver is required (with the generic Microsoft usbser driver the device does not answer at all). On Linux the xr_serial kernel driver (5.12+) should apply (untested). As it is a plain serial port, port=auto does not apply.

The device does not answer APC UPS-Link (Y), Modbus RTU or MicroLink, so apcsmart, apc_modbus and apcmicrolink do not work with this model.

The output was unloaded while this dump was taken, hence ups.load: 0 and a long battery.runtime. Instant commands were only listed, not exercised. The serial number has been redacted.

Reported at:

Further system data or configuration example:

Driver configuration
[srv]
        driver = nutdrv_qx
        port = COM6
        protocol = voltronic
        desc = "APC Easy UPS On-Line SRV2KI-E"