2.8.5.1168-1168+g2caa3c875

This device is known to work with driver apcmicrolink.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.date

2021-11-30

battery.date.maintenance

2031-12-29

battery.lifetime.status

LifeTimeStatusOK

battery.lowruntimewarning

120

battery.runtime

2830

battery.temperature

31.195312

battery.voltage

15.9375

device.mfr

APC

device.model

Smart-UPS 500

device.part

SCL500RM1UC

device.serial

5S2145T34657

device.type

ups

driver.debug

0

driver.flag.allow_killpower

0

driver.name

apcmicrolink

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.productid

0003

driver.parameter.synchronous

auto

driver.parameter.vendorid

051d

driver.state

updateinfo

driver.version

2.8.5.1168-1168+g2caa3c875

driver.version.internal

0.03

driver.version.usb

libusb-1.0.28 (API: 0x0100010A)

experimental.battery.firmware

3Ah2_v1001

experimental.battery.part

APCRBC167-LI

experimental.battery.serial

9H2417X10631

experimental.microlink.battery.test.schedule

OnStartUp14Since

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

experimental.microlink.diag.auth_refused

0

experimental.microlink.diag.auth_status

0x0001

experimental.microlink.diag.hid_fallback.active

0

experimental.microlink.diag.slave_password_echo

5c476804

experimental.microlink.ups.test.result

Passed

experimental.outlet.group.0.status.cause

UPSStatusChange

experimental.outlet.group.1.status.cause

SystemInitialization UPSStatusChange

experimental.outlet.group.2.status.cause

UPSStatusChange

experimental.output.energy

79123

experimental.output.voltage.setting

VAC230

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

experimental.statistics.battery.totaltime

731

experimental.statistics.battery.transfers

43

experimental.statistics.input.totaltime

75496349

experimental.statistics.output.totaltime

75497153

experimental.statistics.ups.totaltime

75497279

experimental.ups.load.apparent

13.042969

input.frequency

50.007812

input.quality

Acceptable

input.sensitivity

normal

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

input.transfer.high

253

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

input.transfer.low

207

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

input.transfer.reason

AcceptableInput

input.voltage

231.078125

outlet.group.0.delay.reboot

8

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.0.delay.shutdown

180

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.0.delay.start

0

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.0.minimumreturnruntime

0

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.0.name

Unswitched Group

This variable can be set through upsrw to a string value upto the length of 16 characters.

outlet.group.0.status

StateOn

outlet.group.0.switchable

no

outlet.group.1.delay.reboot

8

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.1.delay.shutdown

180

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.1.delay.start

0

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.1.lowruntimewarning

0

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.1.minimumreturnruntime

0

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.1.name

Group 1

This variable can be set through upsrw to a string value upto the length of 16 characters.

outlet.group.1.status

StateOn

outlet.group.1.switchable

yes

outlet.group.1.timer.reboot

NotActive

outlet.group.1.timer.shutdown

NotActive

outlet.group.1.timer.start

NotActive

outlet.group.2.delay.reboot

8

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.2.delay.shutdown

180

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.2.delay.start

0

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.2.lowruntimewarning

0

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.2.minimumreturnruntime

0

settable (upsrw), reported Type: NUMBER with no declared range — see DEVICE:COMMENT above

outlet.group.2.name

Group 2

This variable can be set through upsrw to a string value upto the length of 16 characters.

outlet.group.2.status

StateOn

outlet.group.2.switchable

yes

outlet.group.2.timer.reboot

NotActive

outlet.group.2.timer.shutdown

NotActive

outlet.group.2.timer.start

NotActive

outlet.group.count

3

output.current

0.28125

output.frequency

50

output.voltage

231.078125

ups.beeper.status

enabled

ups.id

APC UPS test

This variable can be set through upsrw to a string value upto the length of 16 characters.

ups.load

9.75

ups.mfr

APC

ups.mfr.date

2021-11-30

ups.model

Smart-UPS 500

ups.power

65.2148

ups.power.nominal

500

ups.productid

0004

ups.realpower

39

ups.realpower.nominal

400

ups.serial

5S2145T34657

ups.status

OL

ups.temperature

31.195312

ups.test.interval

1209600

ups.test.result

Passed

ups.vendorid

051d

Known supported commands

This device is known to support the following NUT’s instant commands:

  • beeper.disable

  • beeper.enable

  • bypass.start

  • bypass.stop

  • calibrate.start

  • calibrate.stop

  • driver.killpower

  • driver.reload

  • load.cycle

  • load.off

  • load.off.delay

  • load.on

  • load.on.delay

  • outlet.group.1.load.cycle

  • outlet.group.1.load.off

  • outlet.group.1.load.off.delay

  • outlet.group.1.load.on

  • outlet.group.1.load.on.delay

  • outlet.group.1.shutdown.default

  • outlet.group.1.shutdown.reboot

  • outlet.group.1.shutdown.reboot.graceful

  • outlet.group.1.shutdown.return

  • outlet.group.1.shutdown.stayoff

  • outlet.group.2.load.cycle

  • outlet.group.2.load.off

  • outlet.group.2.load.off.delay

  • outlet.group.2.load.on

  • outlet.group.2.load.on.delay

  • outlet.group.2.shutdown.default

  • outlet.group.2.shutdown.reboot

  • outlet.group.2.shutdown.reboot.graceful

  • outlet.group.2.shutdown.return

  • outlet.group.2.shutdown.stayoff

  • shutdown.default

  • shutdown.reboot

  • shutdown.reboot.graceful

  • shutdown.return

  • shutdown.stayoff

  • test.battery.start

  • test.battery.stop

  • test.panel.start

apcmicrolink is a new driver (merged via NUT PR #3579, not yet in any tagged NUT release) for APC Smart-UPS units with no serial port, using the AP9641-style "Microlink" protocol tunnelled over USB HID. This report is from an APC Smart-UPS 500 (SCL500RM1UC). Needs the APC/Schneider Electric cable 940-0504 (USB A to USB A) — a standard USB A-to-B cable will not work.

Several settable variables (delays, thresholds, input.sensitivity, battery.date, the outlet-group timer/schedule fields) are reported by upsrw with Type: NUMBER and no declared min/max, which doesn’t map cleanly onto DDL’s STRING/RANGE/ENUM #RW: markup — left as plain comments below rather than guessed at. Only the four genuine STRING variables (three outlet-group names + ups.id, each with a published max length) are given as #RW: tags.

Reported at:

Further system data or configuration example:

Driver configuration
# ups.conf
[scl500]
  driver = apcmicrolink
  port = auto
  vendorid = 051d
  productid = 0003
  desc = "APC Smart-UPS 500 (SCL500RM1UC), USB HID tunnel"