Report #1 with driver nutdrv_qx (detailed comments available)

This device is known to work with driver nutdrv_qx.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100.0

battery.runtime

1860

battery.temperature

33.1

battery.voltage

13.5

battery.voltage.high

26.00

battery.voltage.low

20.80

battery.voltage.nominal

24

device.serial

REDACTED

device.type

ups

driver.debug

0

driver.flag.allow_killpower

0

driver.name

nutdrv_qx

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

auto

driver.state

quiet

driver.version

2.8.5.1711.1-1712+g46d8d8c81

driver.version.data

Omron 0.01

driver.version.internal

0.58

driver.version.usb

libusb-1.0.30 (API: 0x0100010C)

input.frequency

60.1

input.voltage

101.5

input.voltage.fault

0.0

output.frequency

60.0

output.voltage

101.6

ups.delay.shutdown

30

ups.delay.start

180

ups.firmware

0.33

ups.firmware.aux

1.04

ups.load

23

ups.power.nominal

550

ups.productid

00d0

ups.realpower.nominal

340

ups.serial

REDACTED

ups.status

OL

ups.temperature

35.3

ups.type

offline / line interactive

ups.vendorid

0590

Device dump generated by nut-ddl-dump.sh on Sat, 21 Nov 2026 12:47:15 +0900

Further system data or configuration examples:

Variables per upsrw omron@localhost listing
# TODO: Convert to RW:... and RO:... markup
:; upsrw omron@localhost
[driver.debug]
Current debug verbosity level of the driver program
Type: NUMBER
Value: 4

[driver.flag.allow_killpower]
Safety flip-switch to allow the driver daemon to send UPS shutdown command (accessible via driver.killpower)
Type: NUMBER
Value: 0

[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: RANGE NUMBER
Option: "12-600" SELECTED

[ups.delay.start]
Interval to wait before (re)starting the load (seconds)
Type: RANGE NUMBER
Option: "0-599940" SELECTED
Commands per upscmd -l omron@localhost listing
# TODO: Convert to CMD:... markup
:; upscmd -l omron@localhost
Instant commands supported on UPS [omron]:

driver.killpower - Tell the driver daemon to initiate UPS shutdown; should be unlocked with driver.flag.allow_killpower option or variable setting
driver.reload - Reload running driver configuration from the file system (only works for changes in some options)
driver.reload-or-error - Reload running driver configuration from the file system (only works for changes in some options); return an error if something changed and could not be applied live (so the caller can restart it with new options)
driver.reload-or-exit - Reload running driver configuration from the file system (only works for changes in some options); exit the running driver if something changed and could not be applied live (so service management framework can restart it with new options)
shutdown.default - Run the driver-defined UPS shutdown sequence (as opposed to user-configured 'sdcommands')
shutdown.return - Turn off the load and return when power is back
shutdown.stayoff - Turn off the load and remain off
shutdown.stop - Stop a shutdown in progress