Click here to see reports of other supported models from APC.
|
When a user reports that a variable/command is not right then it will be highlighted by a red underline. Bad values/ranges/etc… will get a red dashed outline or red solid left border. The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left. |
2.8.1
Report #1 with driver usbhid-ups (detailed comments available)
This device is known to work with driver usbhid-ups.
You can grab a dummy-ups compliant .dev file to simulate this device clicking here.
Some more detailed comments are available after the "Known supported…" sections.
Known supported variables
This device is known to support the following variables (values are just examples):
|
battery.charge
|
|
|
battery.charge.low
|
|
|
battery.mfr.date
|
|
|
battery.runtime
|
|
|
battery.runtime.low
|
|
|
battery.type
|
|
|
battery.voltage
|
|
|
battery.voltage.nominal
|
|
|
device.mfr
|
|
|
device.model
|
|
|
device.serial
|
|
|
device.type
|
|
|
driver.debug
|
|
|
driver.flag.allow_killpower
|
|
|
driver.flag.ignorelb
|
|
|
driver.name
|
|
|
driver.parameter.override.battery.charge.low
|
|
|
driver.parameter.override.battery.runtime.low
|
|
|
driver.parameter.pollfreq
|
|
|
driver.parameter.pollinterval
|
|
|
driver.parameter.port
|
|
|
driver.parameter.productid
|
|
|
driver.parameter.serial
|
|
|
driver.parameter.synchronous
|
|
|
driver.parameter.vendorid
|
|
|
driver.state
|
|
|
driver.version
|
|
|
driver.version.data
|
|
|
driver.version.internal
|
|
|
driver.version.usb
|
|
|
input.sensitivity
|
|
|
input.transfer.high
|
|
|
input.transfer.low
|
|
|
input.voltage
|
|
|
input.voltage.nominal
|
|
|
ups.beeper.status
|
|
|
ups.delay.shutdown
|
|
|
ups.load
|
|
|
ups.mfr
|
|
|
ups.mfr.date
|
|
|
ups.model
|
|
|
ups.productid
|
|
|
ups.realpower.nominal
|
|
|
ups.serial
|
|
|
ups.status
|
|
|
ups.test.result
|
|
|
ups.timer.reboot
|
|
|
ups.timer.shutdown
|
|
|
ups.vendorid
|
|
About this device
APC Back-UPS BX2200MI (230V, 1200 W) on Debian 13 (trixie), NUT 2.8.1 from the Debian packages (2.8.1-5). Device dump generated by nut-ddl-dump.sh on Thu, 12 Nov 2026 09:24:51 +0300. Serial numbers are masked.
In daily use since Aug 2026: OL/OB switching (incl. a real outage), charge,
runtime, load, input voltage and the battery self-test all work.
There’s no temperature, output.voltage or ups.firmware variable.
battery.charge.low and battery.runtime.low below are overrides from
ups.conf; the device’s own values are 10 and 120.
Known quirks with this NUT version:
-
A few times a day
ups.statusflips toOL RB(sometimesOL LBwithbattery.charge: 0) for one reading while the other values stay normal, same as https://github.com/networkupstools/nut/issues/2347 and https://github.com/networkupstools/nut/issues/3623. -
Since 21 Aug 2026 the driver logs an I/O error every ~32 s, i.e. once per full poll (see the log block below). It survived host reboots and a UPS power cycle. Readings and OB detection aren’t affected.
Vendor/Manufacturer information:
Further system data or configuration examples:
[apc]
driver = "usbhid-ups"
port = "auto"
vendorid = "051D"
productid = "0002"
serial = "XXXXXXXXXXXX"
ignorelb
override.battery.runtime.low = 300
override.battery.charge.low = 20
%s listing:; lsusb
ID 051d:0002 American Power Conversion Uninterruptible Power Supply
106 nut_libusb_get_report: Input/Output Error
upsrw apc@localhost listing# TODO: Convert to RW:... and RO:... markup
:; upsrw apc@localhost
[battery.mfr.date]
Battery manufacturing date
Type: STRING
Maximum length: 10
Value: 2026/08/14
[driver.debug]
Current debug verbosity level of the driver program
Type: NUMBER
Value: 0
[driver.flag.allow_killpower]
Safety flip-switch to allow the driver daemon to send UPS shutdown command (accessible via driver.killpower)
Type: NUMBER
Value: 0
[input.sensitivity]
Input power sensitivity
Type: STRING
Maximum length: 10
Value: medium
[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 295
[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 145
[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
upscmd -l apc@localhost listing# TODO: Convert to CMD:... markup
:; upscmd -l apc@localhost
Instant commands supported on UPS [apc]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
driver.killpower - Tell the driver daemon to initiate UPS shutdown; should be unlocked with driver.flag.allow_killpower option or variable setting
driver.reload - Reload running driver configuration from the file system (only works for changes in some options)
driver.reload-or-error - Reload running driver configuration from the file system (only works for changes in some options); return an error if something changed and could not be applied live (so the caller can restart it with new options)
driver.reload-or-exit - Reload running driver configuration from the file system (only works for changes in some options); exit the running driver if something changed and could not be applied live (so service management framework can restart it with new options)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test