Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from APC.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.8.1

Report #1 with driver usbhid-ups (detailed comments available)

This device is known to work with driver usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

20

battery.mfr.date

2026/08/14

battery.runtime

3816

battery.runtime.low

300

battery.type

PbAc

battery.voltage

27.2

battery.voltage.nominal

24.0

device.mfr

American Power Conversion

device.model

Back-UPS BX2200MI

device.serial

XXXXXXXXXXXX

device.type

ups

driver.debug

0

driver.flag.allow_killpower

0

driver.flag.ignorelb

enabled

driver.name

usbhid-ups

driver.parameter.override.battery.charge.low

20

driver.parameter.override.battery.runtime.low

300

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.productid

0002

driver.parameter.serial

XXXXXXXXXXXX

driver.parameter.synchronous

auto

driver.parameter.vendorid

051D

driver.state

updateinfo

driver.version

2.8.1

driver.version.data

APC HID 0.100

driver.version.internal

0.52

driver.version.usb

libusb-1.0.28 (API: 0x100010a)

input.sensitivity

medium

input.transfer.high

295

input.transfer.low

145

input.voltage

228.0

input.voltage.nominal

230

ups.beeper.status

disabled

ups.delay.shutdown

20

ups.load

5

ups.mfr

American Power Conversion

ups.mfr.date

2026/01/31

ups.model

Back-UPS BX2200MI

ups.productid

0002

ups.realpower.nominal

1200

ups.serial

XXXXXXXXXXXX

ups.status

OL

ups.test.result

Done and passed

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.vendorid

051d

About this device

APC Back-UPS BX2200MI (230V, 1200 W) on Debian 13 (trixie), NUT 2.8.1 from the Debian packages (2.8.1-5). Device dump generated by nut-ddl-dump.sh on Thu, 12 Nov 2026 09:24:51 +0300. Serial numbers are masked.

In daily use since Aug 2026: OL/OB switching (incl. a real outage), charge, runtime, load, input voltage and the battery self-test all work. There’s no temperature, output.voltage or ups.firmware variable.

battery.charge.low and battery.runtime.low below are overrides from ups.conf; the device’s own values are 10 and 120.

Known quirks with this NUT version:

Vendor/Manufacturer information:

Further system data or configuration examples:

Driver configuration
[apc]
    driver = "usbhid-ups"
    port = "auto"
    vendorid = "051D"
    productid = "0002"
    serial = "XXXXXXXXXXXX"
    ignorelb
    override.battery.runtime.low = 300
    override.battery.charge.low = 20
%s listing
:; lsusb
ID 051d:0002 American Power Conversion Uninterruptible Power Supply
journalctl -u nut-driver@apc, last hour, counted
    106 nut_libusb_get_report: Input/Output Error
Variables per upsrw apc@localhost listing
# TODO: Convert to RW:... and RO:... markup
:; upsrw apc@localhost
[battery.mfr.date]
Battery manufacturing date
Type: STRING
Maximum length: 10
Value: 2026/08/14

[driver.debug]
Current debug verbosity level of the driver program
Type: NUMBER
Value: 0

[driver.flag.allow_killpower]
Safety flip-switch to allow the driver daemon to send UPS shutdown command (accessible via driver.killpower)
Type: NUMBER
Value: 0

[input.sensitivity]
Input power sensitivity
Type: STRING
Maximum length: 10
Value: medium

[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 295

[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 145

[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
Commands per upscmd -l apc@localhost listing
# TODO: Convert to CMD:... markup
:; upscmd -l apc@localhost
Instant commands supported on UPS [apc]:

beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
driver.killpower - Tell the driver daemon to initiate UPS shutdown; should be unlocked with driver.flag.allow_killpower option or variable setting
driver.reload - Reload running driver configuration from the file system (only works for changes in some options)
driver.reload-or-error - Reload running driver configuration from the file system (only works for changes in some options); return an error if something changed and could not be applied live (so the caller can restart it with new options)
driver.reload-or-exit - Reload running driver configuration from the file system (only works for changes in some options); exit the running driver if something changed and could not be applied live (so service management framework can restart it with new options)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test