Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from APC.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.8.3.1

Report #1 with driver _usbhid-ups (detailed comments available)

This device is known to work with driver _usbhid-ups.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

10

battery.mfr.date

2001/01/01

battery.runtime

823

battery.runtime.low

120

battery.type

PbAc

battery.voltage

13.3

battery.voltage.nominal

12.0

device.mfr

American Power Conversion

device.model

Back-UPS BVK750M2

device.serial

0B2437P02104

device.type

ups

driver.debug

0

driver.flag.allow_killpower

0

driver.name

usbhid-ups

driver.parameter.interrupt_pipe_no_events_tolerance

-1

driver.parameter.lbrb_log_delay_without_calibrating

1

driver.parameter.onlinedischarge_calibration

1

driver.parameter.pollfreq

30

driver.parameter.pollinterval

2

driver.parameter.port

auto

driver.parameter.synchronous

auto

driver.state

quiet

driver.version

2.8.3.1

driver.version.data

APC HID 0.100

driver.version.internal

0.62

driver.version.usb

libusb-1.0.0 (API: 0x01000102)

input.sensitivity

medium

input.transfer.high

143

input.transfer.low

91

input.voltage

120.0

input.voltage.nominal

120

ups.beeper.status

enabled

ups.delay.shutdown

20

ups.firmware

309500G -397200G

ups.load

38

ups.mfr

American Power Conversion

ups.mfr.date

2024/09/10

ups.model

Back-UPS BVK750M2

ups.productid

0002

ups.realpower.nominal

410

ups.serial

0B2437P02104

ups.status

OL

ups.test.result

Done and passed

ups.timer.reboot

0

ups.timer.shutdown

-1

ups.vendorid

051d

About this device

Vendor/Manufacturer information:

Further system data or configuration examples:

Variables per upsrw ups@localhost listing
# TODO: Convert to RW:... and RO:... markup
:; upsrw ups@localhost
[battery.charge.low]
Description unavailable
Type: STRING
Maximum length: 10
Value: 10

[battery.mfr.date]
Description unavailable
Type: STRING
Maximum length: 10
Value: 2001/01/01

[battery.runtime.low]
Description unavailable
Type: STRING
Maximum length: 10
Value: 120

[driver.debug]
Description unavailable
Type: NUMBER
Value: 0

[driver.flag.allow_killpower]
Description unavailable
Type: NUMBER
Value: 0

[input.sensitivity]
Description unavailable
Type: STRING
Maximum length: 10
Value: medium

[input.transfer.high]
Description unavailable
Type: STRING
Maximum length: 10
Value: 143

[input.transfer.low]
Description unavailable
Type: STRING
Maximum length: 10
Value: 91

[ups.delay.shutdown]
Description unavailable
Type: STRING
Maximum length: 10
Value: 20
Commands per upscmd -l ups@localhost listing
# TODO: Convert to CMD:... markup
:; upscmd -l ups@localhost
Instant commands supported on UPS [ups]:

beeper.disable - Description unavailable
beeper.enable - Description unavailable
beeper.mute - Description unavailable
beeper.off - Description unavailable
beeper.on - Description unavailable
driver.killpower - Description unavailable
driver.reload - Description unavailable
driver.reload-or-error - Description unavailable
driver.reload-or-exit - Description unavailable
load.off - Description unavailable
load.off.delay - Description unavailable
shutdown.default - Description unavailable
shutdown.reboot - Description unavailable
shutdown.stop - Description unavailable
test.battery.start.deep - Description unavailable
test.battery.start.quick - Description unavailable
test.battery.stop - Description unavailable