Network UPS Tools
Power Devices support
Table of Contents

Click here to see reports of other supported models from MGE UPS SYSTEMS.

Note

When a user reports that a variable/command is not right then it will be highlighted by a red underline.

Bad values/ranges/etc… will get a red dashed outline or red solid left border.

The accompanying explaining comment - if provided - will be emphasized through a red dotted border on the left.

2.0.3

Report #1 with driver mge-shut (detailed comments available)

This device is known to work with driver mge-shut.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

30

battery.runtime

01715

driver.name

mge-shut

driver.parameter.lowbatt

5

driver.parameter.offdelay

120

driver.parameter.port

/dev/cuaa0

driver.version

2.0.3

driver.version.internal

0.65

outlet.0.desc

Main Outlet

outlet.0.id

1

outlet.0.switchable

0

outlet.1.autoswitch.charge.low

0

outlet.1.desc

PowerShare Outlet 1

outlet.1.id

2

outlet.1.switch

1

outlet.1.switchable

1

output.voltage

120

ups.delay.shutdown

-1

ups.delay.start

-1

ups.load

2

ups.mfr

MGE UPS SYSTEMS

ups.power.nominal

1200

ups.serial

unknown

ups.status

OL CHRG

Known supported commands

This device is known to support the following NUT’s instant commands:

  • load.off

  • load.on

  • shutdown.return

  • shutdown.stayoff

  • test.battery.start

  • test.battery.stop

2.0.2

Report #1 with driver mge-shut (detailed comments available)

This device is known to work with driver mge-shut.

You can grab a dummy-ups compliant .dev file to simulate this device clicking here.

Some more detailed comments are available after the "Known supported…" sections.

Known supported variables

This device is known to support the following variables (values are just examples):

battery.charge

100

battery.charge.low

30

battery.runtime

01715

driver.name

mge-shut

driver.parameter.port

/dev/ttyS0

driver.version

2.0.2

driver.version.internal

0.64

outlet.0.desc

Main Outlet

outlet.0.id

1

outlet.0.switchable

0

outlet.1.autoswitch.charge.low

0

outlet.1.desc

PowerShare Outlet 1

outlet.1.id

2

outlet.1.switch

1

outlet.1.switchable

1

output.voltage

120

ups.delay.shutdown

-1

ups.delay.start

-1

ups.load

12

ups.mfr

MGE UPS SYSTEMS

ups.model

ellipse 1200

ups.power.nominal

1200

ups.serial

unknown

ups.status

OL CHRG